Product Overview
The Acumed Anatomic Radial Head Solutions 2 system is designed to provide an anatomic implant to replace the patient’s native radial head.
Designed in conjunction with Shawn W. O’Driscoll, MD, PhD, the Acumed Anatomic Radial Head Solutions 2 system includes 924 head and stem combinations and system-specific instrumentation to help streamline the surgeon’s experience in the operating room.
In addition to the Anatomic Radial Head Solutions 2 system, this set may include the Acutrak 2 Mini and Micro instruments and the Radial Head Plating System at the base of the tray to provide multiple solutions all in one set.
Related Documents
Video Tour
Key Publications
Anatomic Radial Head
1. The dish depth increases with head diameter, which is designed to help improve radiocapitellar wear characteristics over nonanatomic heads and the first generation Acumed Anatomic Radial Head.1,2
2. The implant’s medial surface is contoured to better replicate the lateral trochlear ridge facet, which may help avoid cartilage erosion.2
3. Contouring of the medial side of the head has been further refined to track against the radial notch of the ulna.2
4. The radial head is available in six sizes ranging from 18 to 28 mm, in 2 mm increments.
Standard Stem Implants
- +0–8 mm collar height (2 mm increments).
- Grit blast intended to promote bony ongrowth.
- Designed for a press-fit application.
- 6–12 mm stems (1 mm increments).
- Fluted stem designed to provide rotational stability.
Long Stem Implants
- 10° neck angle.
- Insertion depth.
- Hashed laser marks indicate alignment with Lister's tubercle.
- 5.3 mm.
- Grit blast length.
- Distal stem length.
- Fluted stem designed to provide rotational stability.
- Resection length (measured from bottom of dish).
- Stem diameter.
- Stem length.
Long Stem Implants: 6–12 mm diameters
(TR-SLXX-S)
Reamers
Enhanced System Trays
In a continued effort to provide the most comprehensive radial head fracture solution on the market, Anatomic Radial Head Solutions 2 offers our Anatomic Radial Head prosthesis, Radial Head Plating System, and Acutrak 2 System in one tray.
Features include:
- Rigid container system compatibility
- Full tray modularity, allowing for three packaging options for size- and weight-restricted markets
- Updated caddies and instrumentation, including K-wire measuring gauges for enhanced ease of use
Image Gallery
X-Ray
Trays
Product - Stand-Alone
Citations
1. Bachman DR, Thaveepunsan S, Park S, Fitzsimmons JS, An KN, O’Driscoll SW. The effect of prosthetic radial head geometry on the distribution and magnitude of radiocapitellar joint contact pressures. J Hand Surg Am. 2015;40(2):281-288.
2. Sahu D., et al.,Influence of radial head prosthesis design on radiocapitellar joint contact mechanics., J Shoulder Elbow Surg. 2014.23(4): 456–462. doi: 10.1016/j/jse. 2013.11.028.
3. Shukla, D.R., et al., Canal preparation for prosthetic radial head replacement: rasping versus reaming, J Shoulder Elbow Surg. 2013. 22(11): 1474–9